Generator Installation & Maintenance in Brandon, MS
Call us 24/7: 504-310-4410
Home Standby Generators in Brandon, Mississippi

Generator Installation & Maintenance in Brandon, MS

Generator Installation & Maintenance in Brandon, MS

Generator Installation & Maintenance Services in Brandon, MS


From summer storms to hurricane season, Brandon residents and business owners know how quickly the weather can turn. Ready Power provides professional generator installation and maintenance to help you stay powered when it matters most.

Backup Power Solutions for Brandon Homes & Businesses


Whether you’re near the Brandon Amphitheater, in Crossgates, or operating a business off Old Fannin Road, we install reliable generator systems tailored to your needs. We work with trusted brands like Generac and Kohler to ensure peace of mind through any outage.
Contact us today for a free consultation and let’s build a system that works for you.

Proud to Serve the Brandon Community


Founded by Lloyd Huck and Jeremiah Johnson, Ready Power brings decades of combined experience and a team of 16+ to every job. We’ve earned a reputation across the Gulf Coast for being friendly, personable, and true professionals—and we’re excited to now serve the Brandon area.
Follow our social media to see local projects and customer check-ins in your neighborhood.

Seamless Installations, Clear Communication


Worried about the hassle of installation? Don’t be. We make the process easy by showing up on time, communicating clearly, and respecting your space. From small homes to large commercial buildings, we’ve got it covered.
Get your no-pressure quote today and experience a smooth installation process.

Generator Maintenance Made Simple


Generators need routine care to stay ready for hurricane season and beyond. Our maintenance plans help prevent issues and extend the life of your equipment.
Sign up for maintenance reminders and keep your generator ready when you need it most.

Your Generator Experts in Brandon, MS


Ready Power is proud to support the Brandon community with dependable backup power and service you can trust.
Schedule your free consultation today and protect your property with Ready Power.


GET A COMMERCIAL GENERATOR QUOTE TODAY 

Rated 5.0 out of 5 stars based on 625 customer reviews

New Orleans, LA at a glance

Ready Power USA has completed 50 jobs in New Orleans, LA in August 2026.

The 15 customer reviews shown here average 5.0 out of 5.

The most recent job was on August 31, 2026.

Ready Power USA has completed 1,199 jobs in New Orleans, LA in the last 12 months. The first job there was in August 2024.

Job Locations and Reviews

New Orleans, LA - Service
Lennie T.
Lennie T. Checked in
Service
New Orleans, LA 70114
New Orleans, LA - Wwwwweee
Hurt S.
Hurt S. Checked in
Wwwwweee
New Orleans, LA 70125
New Orleans, LA - Generator Service
Lennie T.
Lennie T. Checked in
Generator Service
New Orleans, LA 70118
New Orleans, LA - Start up
Lennie T.
Lennie T. Checked in
Start up
New Orleans, LA 70115
New Orleans, LA - Repair
Lennie T.
Lennie T. Checked in
Repair
New Orleans, LA 70115
New Orleans, LA - Annual maintenance
Lennie T.
Lennie T. Checked in
Annual maintenance
New Orleans, LA 70131
New Orleans, LA - Service
Lennie T.
Lennie T. Checked in
Service
New Orleans, LA 70131
New Orleans, LA - Generator service
Lennie T.
Lennie T. Checked in
Generator service
New Orleans, LA 70131
New Orleans, LA - Annual tuneup complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual tuneup complete no additional work needed.
New Orleans, LA 70118
New Orleans, LA - Annual maintenance complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed.
New Orleans, LA 70118
Review
Mr. Smith did an excellent job, very professional and informed me about the system. I would highly recommend him.
William - New Orleans, LA 70118
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed.
New Orleans, LA 70118
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed
New Orleans, LA 70118
New Orleans, LA - Semi annual inspection complete no additional work needed.
Hurt S.
Hurt S. Checked in
Semi annual inspection complete no additional work needed.
New Orleans, LA 70131
New Orleans, LA - Annual tuneup complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual tuneup complete no additional work needed.
New Orleans, LA 70131
Review
He took care of the maintenance even with the rain.
Mary - New Orleans, LA 70115
Review
Mr Smith was timely and helpful. Appreciated his friendly service and knowledge.
Generator Service - New Orleans, LA 70122
New Orleans, LA - Annual maintenance complete use one maintenance kit and replaced battery.
Hurt S.
Hurt S. Checked in
Annual maintenance complete use one maintenance kit and replaced battery.
New Orleans, LA 70122
Review
Excellent Service
Charles - New Orleans, LA 70126
New Orleans, LA - Annual maintenance complete..
Hurt S.
Hurt S. Checked in
Annual maintenance complete..
New Orleans, LA 70126
Richard C.
Richard C. Checked in
Generator serviced
New Orleans, LA 70124
Review
I needed some questions answered and I got what I needed!
Kevin - New Orleans, LA 70122
Review
Satisfied
Allan - New Orleans, LA 70115
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70114
Review
Great service!
Elaine - New Orleans, LA 70119
Gabriel B.
Gabriel B. Checked in
Generator service and SMM repair
New Orleans, LA 70119
Review
great
John - New Orleans, LA 70117
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70117
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70117
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70119
New Orleans, LA - Replace Smart management module with a new one.
Hurt S.
Hurt S. Checked in
Replace Smart management module with a new one.
New Orleans, LA 70115
New Orleans, LA - Annual maintenance complete use one maintenance kit and replace battery.
Hurt S.
Hurt S. Checked in
Annual maintenance complete use one maintenance kit and replace battery.
New Orleans, LA 70115
New Orleans, LA - Annual maintenance complete use one maintenance kit no additional work needed.
Hurt S.
Hurt S. Checked in
Annual maintenance complete use one maintenance kit no additional work needed.
New Orleans, LA 70115
New Orleans, LA - Annual maintenance complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed.
New Orleans, LA 70115
Review
Excellent service!
Jonathan - New Orleans, LA 70118
Review
Came on time was thorough and detailed
Sherif - New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
New Orleans, LA - Annual tuneup complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual tuneup complete no additional work needed.
New Orleans, LA 70118
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70118
Review
Prompt, polite, efficient
OAR. - New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
New Orleans, LA - Semi annual inspection complete no additional work needed
Hurt S.
Hurt S. Checked in
Semi annual inspection complete no additional work needed
New Orleans, LA 70130
New Orleans, LA - Annual maintenance complete.
Hurt S.
Hurt S. Checked in
Annual maintenance complete.
New Orleans, LA 70115
Review
He was very professional and friendly
Sheila - New Orleans, LA 70131
New Orleans, LA - Unit did not exercise yesterday (Monday) at 3:00 because the date/time was inaccurate, and needed to be adjusted. I performed a hard reset and firmware update on the controller before fixing the date/time settings. After that, I set the exercise for today at 10:30 to make sure it ran, and it ran a full exercise. The unit will now stay on its weekly exercise schedule, and is fully operational.
Michael H.
Michael H. Checked in
Unit did not exercise yesterday (Monday) at 3:00 because the date/time was inaccurate, and needed to be adjusted. I performed a hard reset and firmware update on the controller before fixing the date/time settings. After that, I set the exercise for today at 10:30 to make sure it ran, and it ran a full exercise. The unit will now stay on its weekly exercise schedule, and is fully operational.
New Orleans, LA 70131
New Orleans, LA - Unit was getting consistent charger warnings, and hasn’t exercised since 7/28/26. Upon closer inspection, I found the positive battery terminal to be completely corroded to the point that there was no metal left. I replaced the positive battery terminal, and the battery, which was from 2021. The unit is now fully operational, and completed a load transfer test.
Michael H.
Michael H. Checked in
Unit was getting consistent charger warnings, and hasn’t exercised since 7/28/26. Upon closer inspection, I found the positive battery terminal to be completely corroded to the point that there was no metal left. I replaced the positive battery terminal, and the battery, which was from 2021. The unit is now fully operational, and completed a load transfer test.
New Orleans, LA 70131
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70130
Review
Didn’t wait long
Mia - New Orleans, LA 70124
New Orleans, LA - Upon arrival, the unit was left open, and it was raining hard. The controller sustained damage, and needs to be replaced before proceeding with diagnostic.
Michael H.
Michael H. Checked in
Upon arrival, the unit was left open, and it was raining hard. The controller sustained damage, and needs to be replaced before proceeding with diagnostic.
New Orleans, LA 70124
New Orleans, LA - Untis fully operational, and did transfer when power was lost on 7/28/26 after a car hit a pole. Power in the house was not on becuase the main panel breaker was tripped.
Michael H.
Michael H. Checked in
Untis fully operational, and did transfer when power was lost on 7/28/26 after a car hit a pole. Power in the house was not on becuase the main panel breaker was tripped.
New Orleans, LA 70122
Review
Excellent Service
David - New Orleans, LA 70122
New Orleans, LA - 
Controller has been replaced, and a load test was completed. The unit is fully operational.
Michael H.
Michael H. Checked in
Controller has been replaced, and a load test was completed. The unit is fully operational.
New Orleans, LA 70122
New Orleans, LA - Upon arrival, unit was shutdown with a 1300 low oil pressure code. I tested the switch, and when I ran it, the switch would leak oil, so I replaced it. Also, I found that the battery had not been changed at the recent maintenance even though it was over 3 years old, so I changed it out. After replacing the oil pressure switch, I performed a load test to ensure proper operation. The unit ran but failed to transfer to standby, so I began further diagnosis. I found that wire 194 and 23 was only reading  1.6 VDC at the SACM, but when I disconnected 194, it read proper battery voltage. This led me to replace the ISACM, where I found that a lizard had shorted the circuit on the back, which also damaged the ICE cube relay, causing the unit to not transfer. We will need to come back to replace the ICE cube relay. Unit was left in the OFF position.
Michael H.
Michael H. Checked in
Upon arrival, unit was shutdown with a 1300 low oil pressure code. I tested the switch, and when I ran it, the switch would leak oil, so I replaced it. Also, I found that the battery had not been changed at the recent maintenance even though it was over 3 years old, so I changed it out. After replacing the oil pressure switch, I performed a load test to ensure proper operation. The unit ran but failed to transfer to standby, so I began further diagnosis. I found that wire 194 and 23 was only reading 1.6 VDC at the SACM, but when I disconnected 194, it read proper battery voltage. This led me to replace the ISACM, where I found that a lizard had shorted the circuit on the back, which also damaged the ICE cube relay, causing the unit to not transfer. We will need to come back to replace the ICE cube relay. Unit was left in the OFF position.
New Orleans, LA 70122
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70119
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70115
Review
Fixed immediately!
Lisa - New Orleans, LA 70115
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70115
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70115
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70122
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70122
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70124
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70124