Generator Installation & Maintenance in Natchez, MS
Call us 24/7: 504-310-4410
Home Standby Generators in Natchez, Mississippi

Generator Installation & Maintenance in Natchez, MS

Generator Installation & Maintenance in Natchez, MS

Generator Installation & Maintenance in Natchez, MS – Stay Powered, Rain or Shine


Reliable Backup Power for Natchez Homes & Businesses

Living in Natchez means enjoying historic beauty—but it also means preparing for hurricanes, flooding, and strong storms that threaten power stability. Whether you're near the Natchez Trace Parkway or in the heart of the Historic Downtown District, Ready Power offers professional generator installation and maintenance designed to protect your home or business through every season.
→ Contact us today for a free consultation and be ready for whatever comes next.


Installation That’s Smooth, Clean, and Easy

Think generator installation is a hassle? Not with us. Founded by Lloyd Huck and Jeremiah Johnson, our 16+ person team is known for being friendly, respectful, and efficient. We make the process simple—from permitting to final walkthrough—so you don’t have to stress.
→ Follow us on social to see recent installations and customer feedback around Natchez.


Maintenance Plans That Keep You Prepared

Generators need care to perform when you need them most. That’s why we offer flexible maintenance plans and convenient reminders, keeping your system storm-ready at all times—especially during Mississippi’s most unpredictable seasons.
→ Sign up for maintenance reminders and stay one step ahead.


Affordable, Pressure-Free Power Solutions

Worried about the cost or complexity? We get it. That’s why we guide you through options from trusted brands like Generac and Kohler—always with honest, no-pressure recommendations. Whether you’re powering a home in Concord or a business along the Bluff, we’ll find the right fit.
→ Request your free, no-obligation quote today.


Proud to Power the Natchez Community

Now serving Natchez, Ready Power is here to help residents and businesses stay protected with trusted expertise and a personable approach.
→ Have questions? Give us a call—we’re here to help.


"The team was extremely knowledgeable and kept me in the loop every step of the way. Best service I've ever had."

Rated 5.0 out of 5 stars based on 625 customer reviews

New Orleans, LA at a glance

Ready Power USA has completed 50 jobs in New Orleans, LA in August 2026.

The 15 customer reviews shown here average 5.0 out of 5.

The most recent job was on August 31, 2026.

Ready Power USA has completed 1,199 jobs in New Orleans, LA in the last 12 months. The first job there was in August 2024.

Job Locations and Reviews

New Orleans, LA - Service
Lennie T.
Lennie T. Checked in
Service
New Orleans, LA 70114
New Orleans, LA - Wwwwweee
Hurt S.
Hurt S. Checked in
Wwwwweee
New Orleans, LA 70125
New Orleans, LA - Generator Service
Lennie T.
Lennie T. Checked in
Generator Service
New Orleans, LA 70118
New Orleans, LA - Start up
Lennie T.
Lennie T. Checked in
Start up
New Orleans, LA 70115
New Orleans, LA - Repair
Lennie T.
Lennie T. Checked in
Repair
New Orleans, LA 70115
New Orleans, LA - Annual maintenance
Lennie T.
Lennie T. Checked in
Annual maintenance
New Orleans, LA 70131
New Orleans, LA - Service
Lennie T.
Lennie T. Checked in
Service
New Orleans, LA 70131
New Orleans, LA - Generator service
Lennie T.
Lennie T. Checked in
Generator service
New Orleans, LA 70131
New Orleans, LA - Annual tuneup complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual tuneup complete no additional work needed.
New Orleans, LA 70118
New Orleans, LA - Annual maintenance complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed.
New Orleans, LA 70118
Review
Mr. Smith did an excellent job, very professional and informed me about the system. I would highly recommend him.
William - New Orleans, LA 70118
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed.
New Orleans, LA 70118
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed
New Orleans, LA 70118
New Orleans, LA - Semi annual inspection complete no additional work needed.
Hurt S.
Hurt S. Checked in
Semi annual inspection complete no additional work needed.
New Orleans, LA 70131
New Orleans, LA - Annual tuneup complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual tuneup complete no additional work needed.
New Orleans, LA 70131
Review
He took care of the maintenance even with the rain.
Mary - New Orleans, LA 70115
Review
Mr Smith was timely and helpful. Appreciated his friendly service and knowledge.
Generator Service - New Orleans, LA 70122
New Orleans, LA - Annual maintenance complete use one maintenance kit and replaced battery.
Hurt S.
Hurt S. Checked in
Annual maintenance complete use one maintenance kit and replaced battery.
New Orleans, LA 70122
Review
Excellent Service
Charles - New Orleans, LA 70126
New Orleans, LA - Annual maintenance complete..
Hurt S.
Hurt S. Checked in
Annual maintenance complete..
New Orleans, LA 70126
Richard C.
Richard C. Checked in
Generator serviced
New Orleans, LA 70124
Review
I needed some questions answered and I got what I needed!
Kevin - New Orleans, LA 70122
Review
Satisfied
Allan - New Orleans, LA 70115
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70114
Review
Great service!
Elaine - New Orleans, LA 70119
Gabriel B.
Gabriel B. Checked in
Generator service and SMM repair
New Orleans, LA 70119
Review
great
John - New Orleans, LA 70117
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70117
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70117
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70119
New Orleans, LA - Replace Smart management module with a new one.
Hurt S.
Hurt S. Checked in
Replace Smart management module with a new one.
New Orleans, LA 70115
New Orleans, LA - Annual maintenance complete use one maintenance kit and replace battery.
Hurt S.
Hurt S. Checked in
Annual maintenance complete use one maintenance kit and replace battery.
New Orleans, LA 70115
New Orleans, LA - Annual maintenance complete use one maintenance kit no additional work needed.
Hurt S.
Hurt S. Checked in
Annual maintenance complete use one maintenance kit no additional work needed.
New Orleans, LA 70115
New Orleans, LA - Annual maintenance complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual maintenance complete no additional work needed.
New Orleans, LA 70115
Review
Excellent service!
Jonathan - New Orleans, LA 70118
Review
Came on time was thorough and detailed
Sherif - New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
New Orleans, LA - Annual tuneup complete no additional work needed.
Hurt S.
Hurt S. Checked in
Annual tuneup complete no additional work needed.
New Orleans, LA 70118
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70118
Review
Prompt, polite, efficient
OAR. - New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70118
New Orleans, LA - Semi annual inspection complete no additional work needed
Hurt S.
Hurt S. Checked in
Semi annual inspection complete no additional work needed
New Orleans, LA 70130
New Orleans, LA - Annual maintenance complete.
Hurt S.
Hurt S. Checked in
Annual maintenance complete.
New Orleans, LA 70115
Review
He was very professional and friendly
Sheila - New Orleans, LA 70131
New Orleans, LA - Unit did not exercise yesterday (Monday) at 3:00 because the date/time was inaccurate, and needed to be adjusted. I performed a hard reset and firmware update on the controller before fixing the date/time settings. After that, I set the exercise for today at 10:30 to make sure it ran, and it ran a full exercise. The unit will now stay on its weekly exercise schedule, and is fully operational.
Michael H.
Michael H. Checked in
Unit did not exercise yesterday (Monday) at 3:00 because the date/time was inaccurate, and needed to be adjusted. I performed a hard reset and firmware update on the controller before fixing the date/time settings. After that, I set the exercise for today at 10:30 to make sure it ran, and it ran a full exercise. The unit will now stay on its weekly exercise schedule, and is fully operational.
New Orleans, LA 70131
New Orleans, LA - Unit was getting consistent charger warnings, and hasn’t exercised since 7/28/26. Upon closer inspection, I found the positive battery terminal to be completely corroded to the point that there was no metal left. I replaced the positive battery terminal, and the battery, which was from 2021. The unit is now fully operational, and completed a load transfer test.
Michael H.
Michael H. Checked in
Unit was getting consistent charger warnings, and hasn’t exercised since 7/28/26. Upon closer inspection, I found the positive battery terminal to be completely corroded to the point that there was no metal left. I replaced the positive battery terminal, and the battery, which was from 2021. The unit is now fully operational, and completed a load transfer test.
New Orleans, LA 70131
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70130
Review
Didn’t wait long
Mia - New Orleans, LA 70124
New Orleans, LA - Upon arrival, the unit was left open, and it was raining hard. The controller sustained damage, and needs to be replaced before proceeding with diagnostic.
Michael H.
Michael H. Checked in
Upon arrival, the unit was left open, and it was raining hard. The controller sustained damage, and needs to be replaced before proceeding with diagnostic.
New Orleans, LA 70124
New Orleans, LA - Untis fully operational, and did transfer when power was lost on 7/28/26 after a car hit a pole. Power in the house was not on becuase the main panel breaker was tripped.
Michael H.
Michael H. Checked in
Untis fully operational, and did transfer when power was lost on 7/28/26 after a car hit a pole. Power in the house was not on becuase the main panel breaker was tripped.
New Orleans, LA 70122
Review
Excellent Service
David - New Orleans, LA 70122
New Orleans, LA - 
Controller has been replaced, and a load test was completed. The unit is fully operational.
Michael H.
Michael H. Checked in
Controller has been replaced, and a load test was completed. The unit is fully operational.
New Orleans, LA 70122
New Orleans, LA - Upon arrival, unit was shutdown with a 1300 low oil pressure code. I tested the switch, and when I ran it, the switch would leak oil, so I replaced it. Also, I found that the battery had not been changed at the recent maintenance even though it was over 3 years old, so I changed it out. After replacing the oil pressure switch, I performed a load test to ensure proper operation. The unit ran but failed to transfer to standby, so I began further diagnosis. I found that wire 194 and 23 was only reading  1.6 VDC at the SACM, but when I disconnected 194, it read proper battery voltage. This led me to replace the ISACM, where I found that a lizard had shorted the circuit on the back, which also damaged the ICE cube relay, causing the unit to not transfer. We will need to come back to replace the ICE cube relay. Unit was left in the OFF position.
Michael H.
Michael H. Checked in
Upon arrival, unit was shutdown with a 1300 low oil pressure code. I tested the switch, and when I ran it, the switch would leak oil, so I replaced it. Also, I found that the battery had not been changed at the recent maintenance even though it was over 3 years old, so I changed it out. After replacing the oil pressure switch, I performed a load test to ensure proper operation. The unit ran but failed to transfer to standby, so I began further diagnosis. I found that wire 194 and 23 was only reading 1.6 VDC at the SACM, but when I disconnected 194, it read proper battery voltage. This led me to replace the ISACM, where I found that a lizard had shorted the circuit on the back, which also damaged the ICE cube relay, causing the unit to not transfer. We will need to come back to replace the ICE cube relay. Unit was left in the OFF position.
New Orleans, LA 70122
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70119
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70115
Review
Fixed immediately!
Lisa - New Orleans, LA 70115
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70115
New Orleans, LA - Generator serviced.
Richard C.
Richard C. Checked in
Generator serviced.
New Orleans, LA 70115
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70122
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70122
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70124
Gabriel B.
Gabriel B. Checked in
Generator service
New Orleans, LA 70124